What evidence should an OEM request after connector corrosion testing?

Request the controlled specimen definition, method and edition, exposure and recovery record, deviations, photographs, acceptance criteria and individual electrical and mechanical results. Link the report to the exact drawing revision and manufacturing lot. Ask JNICON to review available model-specific evidence and unresolved requirements; do not substitute a generic certificate for the required assembly qualification.